Design Considerations for Increasing Snow & Wind Ratings
Commercial Structure Tent Specifications - A Frame Clearspan
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Profile-Sizing.png)
Structure Materials
• Aluminium 6005-T5, clear anodized finish
• Steel ASTM A36 (44W) and A514 Gr.S (CHT100)
• Steel Tube HSS 50W
• Bolts Grade 5
• Flux-cored weld wire DW-50
• Steel parts zinc plated (G164-m92 4.5 mil.)
• Wire Rope 1/4″
Vinyl Materials
• 22 oz coated vinyl
• NFPA 701 / CAN- ULC Fire Retardant
• Blocks UV light
Typically Permitting Materials:
• NFPA 701 / CAN- ULC Fire Retardant Certificate
• Structural Drawings
• Egress Doors
• Site Plan & Floor Plan
• Letter of Intended Use
• Illuminated Exit Lighting
• Lighting Plan
• Sealed PE Engineered Drawings Licensed in the state of construction
![](https://americanstructuretent.com/wp-content/uploads/2023/02/40x.png)
![](https://americanstructuretent.com/wp-content/uploads/2023/02/40x.png)
![](https://americanstructuretent.com/wp-content/uploads/2023/02/40x.png)
![](https://americanstructuretent.com/wp-content/uploads/2023/02/18x.png)
Masters of Structure
Design Considerations for Increasing Snow & Wind Ratings
Design Considerations for Increasing Snow Ratings
– Bay Shortening from 15′ to 10′
– Snow Cross Cable from Eave to Eave
– Center Pole or Leg Supports
– Heated Structure for Ice Melting
SUMMER PURLINS
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Summer-Purlin.png)
WINTER PURLINS
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Winter-Purlin-Kit.png)
Design Considerations for Increasing Snow Ratings
– Bay Shortening from 15′ to 10′
– Snow Cross Cable from Eave to Eave
– Center Pole or Leg Supports
– Heated Structure for Ice Melting
WINTER CABLE
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Winter-Arch-Cable-.png)
EAVE CONNECTION
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Screenshot-2023-02-23-164139.png)
Design Considerations for Increasing Wind Ratings
– Bay Shortening from 15′ to 10′
– Extra Guide Wires
– Increased Ballasting & Weights
– Switch from 42″ Stakes to Industrial Grade Earth Anchors
WINTER CENTER POLE
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Center-Pole.png)
CROWN CONNECTION
![](https://americanstructuretent.com/wp-content/uploads/2023/02/Center-Pole-Detail.png)